Since ANSI/CAN/UL 325:2017, a commercial operator on a monitored circuit will not run in momentary-contact mode without a working, monitored primary entrapment protection device. This page is the map of what Manaras makes for that job, and which device your operator actually needs.
Monitored vs Non-Monitored (The Distinction That Matters)
Monitored devices talk to the operator’s BOARD 070M continuously; if the device fails or goes out of alignment, the board knows and refuses to close the door on momentary contact. These are your *primary* protection devices. Non-monitored devices are *ancillary*, legitimate supplements to a monitored primary or to constant-pressure-to-close operation, never a substitute for one.
The Devices
| Device | Type | Key facts |
|---|---|---|
| PHOTO070 | Monitored photo eye (primary) | Infrared thru-beam, Nema 1, ±2° alignment tilt, 30 ft cable and brackets included; pairs with BOARD 070M |
| PHOTO075 | Non-monitored photo eye (ancillary) | Retro-reflective, IP67, PinPoint LED spot, long range, reflector and 2 m cable included |
| PHOTO077 | Non-monitored photo eye (ancillary) | Thru-beam, IP67, PinPoint LED, long range, brackets and 2 m cable included |
| LIGHTCURTAIN001 | Monitored light curtain (primary) | 3 ft protection height, dense multi-beam barrier, IP67, no external interface box |
| LIGHTCURTAIN002 | Monitored light curtain (primary) | Same design, 6 ft protection height |
| SENSEDGE044U | Non-monitored electric sensing edge | 2-wire NO, cut to length (nearest 1/4″), vertical or horizontal mount; works with BOARD 070E and electromechanical controls |
| SENSEDGE044UM | Monitored electric sensing edge (primary) | Same edge, monitored; requires the Signature Interface Module INTERFACE002 (sold separately) |
Photo Eye, Curtain or Edge?
A single photo eye guards one beam height, fine for most vehicle doors. A light curtain throws a dense barrier of beams 3 or 6 feet up the opening, which is what you want where pedestrians and forklifts mix, or where loads overhang below a single beam’s line. A sensing edge rides the door’s bottom edge itself and reacts to touch, the right answer on doors where the approach can’t be beam-protected, and the usual retrofit path on older doors. Many specifying engineers combine an edge with eyes; the devices are designed to co-exist as primary plus ancillary.
What Fails in the Field
Alignment, wiring damage and plain grime cause most photo eye calls, a forklift-clipped bracket or a fogged lens interrupts the beam as effectively as a person standing in it. On monitored circuits the symptom is always the same: the door refuses to close on momentary contact. One point that causes repeated confusion: on a UL 325 monitored circuit, a failed safety device makes the operator refuse to close. That is correct behaviour, not a malfunction. A door that suddenly will not close, with no other symptom, is very often a photo eye or sensing edge that has failed or drifted out of alignment. Sensing edges fail by conductor fatigue at the wire outlet and by physical damage along the edge; monitored edges add the interface module as one more link to test.
Manufacturer Documents
- PHOTO070 specification sheet
- PHOTO075 specification sheet
- PHOTO077 specification sheet
- LIGHTCURTAIN001 specification sheet
- LIGHTCURTAIN002 specification sheet
- SENSEDGE044U specification sheet
- SENSEDGE044UM specification sheet
- Accessory catalogue (PDF)
These pair with every current operator on the Manaras model reference; the board side is covered on the BOARD 070 and Internet Control page.
Supply and Installation Across Metro Vancouver
We stock, install, align and certify entrapment protection on Manaras operators across Metro Vancouver, including bringing older non-compliant doors up to current UL 325 monitored protection. Call (604) 206-5727.