Skip to content

Parkade Door Remote Cloning Explained

  • Since 2007
  • 24/7 emergency
  • WorkSafeBC compliant
  • Licensed & insured
  • Free estimates

Every strata council eventually hears it: a resident had a copy of their parkade remote made at a kiosk, or a former tenant still gets in. Whether that's a minor annoyance or a security hole depends on one thing: what kind of receiver is on your door. Here's how to tell, and how to manage remotes so a lost one doesn't mean a lost parkade.

A parkade door is only as secure as the list of devices that can open it. With some receivers, there is no list at all. With others, there’s a list, but nobody in the building knows how full it is or who holds what. Parkade door remote cloning becomes a problem in both cases. This article is about managing that, not about how radio codes work. For the technology itself, see our rolling code vs fixed code article.

Parkade Door Remote Cloning Explained: ceiling-mounted parkade gate operator above a strata garage entrance

What “cloning” means for a parkade remote

People use the word for two different things:

  • Copying a remote: making a new transmitter that sends the same signal as an existing one, without the building’s involvement.
  • Adding a remote: programming a new transmitter into the receiver on the door, so the receiver knows it.

The difference matters because only the second one leaves a trace in the receiver’s memory. Whether the first is even possible depends on the receiver.

Parkade door remote cloning on fixed-code receivers

Older and simpler systems use fixed codes set by DIP switches. The manufacturer documents say what that means for a building. Manaras’s RADIORE900 fixed-code receiver “Pairs with an infinite number of identical transmitters.” Its RADIORE901 universal receiver says the same for fixed code: “an infinite number of identical fixed code (dip-switch) transmitters”.

“Identical” is the important word, because that’s what makes parkade door remote cloning so easy on these systems. On a fixed-code system:

  • The receiver doesn’t store a list of remotes. It recognises the switch pattern.
  • Any transmitter set to that pattern opens the door, including one set up by someone outside the building.
  • You can’t remove a single lost remote. The only fix is to change the code at the receiver and reset every remote in the building to match.

That’s why parkade door remote cloning is such a headache on a fixed-code door. Every resident remote is effectively the same key. One lost remote, or one unauthorised copy, means re-coding all of them.

How to tell if your door is fixed code

Open the battery cover of a resident remote. A row of tiny switches usually means DIP-switch fixed code. On Manaras equipment, the Series 900 transmitters (RADIOEM901, 903, 932) are DIP-switch fixed code, and their sheets note they “are not compatible with Rolling Code Technology.” The receiver label and model number confirm it.

Learned-remote receivers: there’s a list, and it fills up

Rolling-code receivers learn each remote individually. That gives a building a list to manage, but the list has a limit:

ReceiverRemote capacity (manufacturer document)Erasing
Manaras RADIORE901 universal receiver, rolling code50 rolling code transmittersSee the receiver instructions
LiftMaster Logic 5.0 operators (built-in receiver)Up to 90 remote controls and up to 30 keyless entry devicesHold the RADIO button about 5 seconds: “All remote controls will be erased”
LiftMaster MAXUM DC operators (built-in receiver)Up to 90 remote controls and up to 30 keyless entry devicesWall-control menu: erase by device type or “Erase all”
LiftMaster STAR1000 access control receiverUp to 1000 remote controls“Supports suspending and unsuspending remote controls”
LiftMaster MAXUM DC with myQ FacilityUp to 1000 remotes through myQ Facility, tied to specific peopleManaged in the myQ Facility software

Two practical points follow from the manuals:

  1. A 90-remote receiver is small for a large building. LiftMaster’s Logic 5.0 manual notes that programming a remote “use[s] 1 channel of the 90 channels”. A building with more remotes than that needs a separate receiver or access system.
  2. On the built-in receivers, deleting one remote isn’t described. The Logic 5.0 and MAXUM DC manuals describe erasing all remotes (or all of one device type), not a single one. To drop one lost remote, you erase and re-learn everyone else’s. Receivers built for this, like STAR1000 with its suspend feature or myQ Facility’s transmitter management, avoid that.

Mixed systems

Manaras’s RADIORE901 accepts both rolling-code and fixed-code transmitters. That’s useful during a changeover, but while any fixed-code remotes are still enabled, the door has the fixed-code weakness described above. Plan a cut-off date.

Running a remote register that actually works

This part is practice, not manuals. A few simple habits go a long way:

  • Keep a register. Unit, name, remote serial or label, date issued, date returned. One spreadsheet, kept by the manager.
  • Know your receiver’s capacity and how many slots are used. If you’re at 85 of 90, plan the upgrade before you run out.
  • Collect remotes at move-out as part of the building’s move-out routine, and update the register the same day.
  • Decide in advance what happens when a remote is lost. On an erase-all receiver, a scheduled “re-learn day” every few months may be easier than re-learning the whole building every time one goes missing.
  • Don’t hand out the programming method. On most operators, adding a remote means access to the control board or a wall-control menu. Keep the control box locked.

When copies are already out there

If you suspect unauthorised copies:

  1. Find out whether the door is fixed code or learned code.
  2. Fixed code: change the code at the receiver and re-set every legitimate remote. Better, plan a move to a learned-code receiver.
  3. Learned code: erase and re-learn only the remotes on your register. Anything that isn’t re-learned stops working.

Beyond remotes: credential-based access

Some buildings move away from remotes as the main credential. LiftMaster’s myQ Facility software lets managers “Assign permission-based facility access by person, group, time and location”, and Chamberlain’s myQ pages say it keeps “a record of who is operating each door, and when.” Manaras’s MIC device lets a building “Share access with multiple users, with either temporary access or permanent access” and needs a monitored Manaras operator with a BOARD070M. Our Manaras MIC setup guide covers that option.

Keypads and card readers are another route. Manaras’s CARDREADER017 card reader / keypad is listed for close-proximity mounting by the door.

Whatever you choose, the receiver on the door should match the size of your remote population. If you’re adding remotes now, our Manaras remote programming guide and replacing a commercial remote yourself cover the basics. For a receiver upgrade or a re-code across the building, book it through our strata parkade door service.

Remote and receiver questions from councils

Can someone copy our parkade remote?

On a fixed-code system, yes in practice. Manaras describes its fixed-code receiver as pairing with an infinite number of identical transmitters, so any transmitter set to the same switch pattern will open the door.

Can we delete one lost remote?

On a fixed-code receiver, no. You change the code and reset every remote. On LiftMaster Logic 5.0 and MAXUM DC built-in receivers the manuals describe erasing all remotes or all of one device type, not a single one. Receivers such as LiftMaster STAR1000 support suspending individual remotes.

How many remotes can a parkade door receiver hold?

It depends on the receiver. The Manaras RADIORE901 holds 50 rolling code transmitters. LiftMaster Logic 5.0 and MAXUM DC built-in receivers hold up to 90 remote controls and 30 keyless entry devices. LiftMaster’s STAR1000 connects up to 1000 remote controls.

How do I know if our parkade remotes are fixed code?

Open a resident remote. A row of small DIP switches usually means fixed code. The model number on the receiver label confirms it.

What should a strata do when a remote is lost?

Record it in the remote register, then follow your receiver’s process: re-code everything on a fixed-code system, erase and re-learn on an erase-all receiver, or suspend that one remote on a receiver that supports it.

Get your parkade remotes under control

Call (604) 206-5727 or use the contact page. We answer around the clock for commercial door failures across Metro Vancouver.

New commercial clients: 10% off labour on your first service call or repair, mention NEW10 when booking (one per business, not combinable with maintenance-contract pricing, work booked by Dec 31, 2026).